Electric chain hoists from 0.5 to 30 tonnes
Cycloid transmission for precision, a double-limit design for reliability and a front-motor clutch for safety. Stationary, electric trolley and heavy duty models.
- Capacity0.5–30 t
- Duty classM5 / 2m
- Control36 VAC
Overview
What is the EGON electric chain hoist?
The EGON T-Series electric chain hoist is a chain hoist for lifting 0.5 to 30 tonnes, built to duty class M5 / 2m and run on AC 380 V, 3 phase, 50 Hz with a 36 VAC control circuit. It comes as a stationary suspension type (ST, 0.5–5 t), an electric trolley standard headroom type (UE, 1–5 t) and a heavy duty type (ST/UE, 10–30 t), each with single-speed or dual-speed lifting.
| Capacity | 0.5 to 30 t |
| Types | Stationary suspension (ST) · Electric trolley, standard headroom (UE) · Heavy duty (ST/UE) |
| Duty class | M5 / 2m (ISO / FEM) |
| Lifting speed | Single speed or dual speed, up to 6.8 m/min |
| Load chain | Imported FEC / G80 super heat-treated alloy steel |
| Power supply | AC 380 V, 3 phase, 50 Hz · control voltage 36 VAC |
| Motor insulation | Class F |


T-Series configurations
Three ways to hang an EGON chain hoist
Pick the configuration first, then the model in the specification tables below.

Stationary suspension type (ST)
A very low distance between the upper and lower hook gives you more working height.

Electric trolley, standard headroom (UE)
The hoist travels along the beam flange on its own electric trolley.

Heavy duty type (ST/UE)
Multi-fall chain hoists with twin lifting motors for heavy loads.
Key features
Built for precise, safe lifting
Cycloid transmission
Higher precision in lifting and lowering.
Double limit switch
Stops lifting and lowering automatically to prevent over-travel.
Front-motor clutch
An extra layer of protection for the hoist and the load.
Power-loss brake
Holds the load instantly when the power supply is cut.
Reverse phase protection
The control circuit will not run if incoming power is connected incorrectly.
36 VAC control voltage
Low control voltage protects the user and the system if current leaks.
G80 alloy load chain
Imported FEC / G80 super heat-treated alloy steel chain.
Enclosed outer case
Light, strong and fully enclosed, with high heat dissipation for harsh sites.
Double-chain saddle design
Lets you configure the suspension scheme flexibly. Fabric or steel chain bag.
How to read an EGON chain hoist model code
EGFH 03-02 UE = rated load 3 t, 2 load chains, electric trolley standard headroom type. ST is the stationary suspension type; ST/UE heavy duty models come in both versions.
Specifications
Electric Chain Hoist specifications
Stationary suspension type (ST), 0.5–5 tElectric trolley, standard headroom type (UE), 1–5 tHeavy duty type (ST/UE), 10–30 t
Stationary suspension type (ST), 0.5–5 t
A very low distance between the upper and lower hook gives you more working height.
Duty class M5 / 2m · Motor insulation class F · Power supply AC 380 V, 3 phase, 50 Hz · Control voltage 36 VAC
| Model | Rated load (t) | Load chains | Chain size (mm) | Lifting speed, single (m/min) | Lifting speed, dual (m/min) | Motor, single (kW) | Motor, dual (kW) |
|---|---|---|---|---|---|---|---|
| EGFH 0.5-01 ST | 0.5 | 1 | 6.3 × 19 | 6.8 | 2.2 / 6.8 | 0.75 | 0.3 / 0.75 |
| EGFH 01-01 ST | 1 | 1 | 7.1 × 21 | 6.8 | 2.2 / 6.8 | 1.5 | 0.6 / 1.5 |
| EGFH 02-01 ST | 2 | 1 | 10 × 30 | 6.8 | 2.2 / 6.8 | 3 | 1.1 / 3.0 |
| EGFH 02-02 ST | 2 | 2 | 7.1 × 21 | 3.4 | 1.1 / 3.4 | 1.5 | 0.6 / 1.5 |
| EGFH 03-01 ST | 3 | 1 | 11.2 × 34 | 5.4 | 1.7 / 5.4 | 3 | 1.1 / 3.0 |
| EGFH 03-02 ST | 3 | 2 | 10 × 30 | 3.4 | 1.1 / 3.4 | 3 | 1.1 / 3.0 |
| EGFH 03-03 ST | 3 | 3 | 7.1 × 21 | 2.3 | 0.7 / 2.3 | 1.5 | 0.6 / 1.5 |
| EGFH 05-02 ST | 5 | 2 | 11.2 × 34 | 2.7 | 0.8 / 2.7 | 3 | 1.1 / 3.0 |
Electric trolley, standard headroom type (UE), 1–5 t
The hoist travels along the beam flange on its own electric trolley.
Duty class M5 / 2m · Motor insulation class F · Power supply AC 380 V, 3 phase, 50 Hz · Control voltage 36 VAC
| Model | Rated load (t) | Load chains | Chain size (mm) | Lifting speed, single (m/min) | Lifting speed, dual (m/min) | Lifting motor, single (kW) | Lifting motor, dual (kW) | Trolley speed, single / dual (m/min) | Trolley motor, single / dual (kW) | Trolley flange width (mm) |
|---|---|---|---|---|---|---|---|---|---|---|
| EGFH 01-01 UE | 1 | 1 | 7.1 × 21 | 6.8 | 2.2 / 6.8 | 1.5 | 0.6 / 1.5 | 11 / 3.6–11 | 0.5 / 0.2–0.5 | 52–153 |
| EGFH 02-01 UE | 2 | 1 | 10 × 30 | TBC | TBC | TBC | TBC | TBC | 0.5 / 0.2–0.5 | 82–178 |
| EGFH 02-02 UE | 2 | 2 | 7.1 × 21 | 3.4 | 1.1 / 3.4 | 1.5 | 0.6 / 1.5 | 11 / 3.6–11 | 0.5 / 0.2–0.5 | 87–178 |
| EGFH 03-01 UE | 3 | 1 | TBC | 5.4 | 1.7 / 5.4 | 3 | 1.1 / 3.0 | 11 / 3.6–11 | 0.5 / 0.2–0.5 | 100–178 |
| EGFH 03-02 UE | 3 | 2 | 10 × 30 | 3.4 | 1.1 / 3.4 | 3.0 | 1.1 / 3.0 | 11 / 3.6–11 | 0.5 / 0.2–0.5 | 100–178 |
| EGFH 03-03 UE | 3 | 3 | 7.1 × 21 | 2.3 | 0.7 / 2.3 | 1.5 | 0.6 / 1.5 | 11 / 3.6–11 | 0.75 / 0.3–0.75 | 100–178 |
| EGFH 05-02 UE | 5 | 2 | TBC | 2.7 | 0.8 / 2.7 | 3.0 | 1.1 / 3.0 | 11 / 3.6–11 | 0.75 / 0.3–0.75 | 100–178 |
Heavy duty type (ST/UE), 10–30 t
Multi-fall chain hoists with twin lifting motors for heavy loads.
Duty class M5 / 2m · Motor insulation class F · Power supply AC 380 V, 3 phase, 50 Hz · Control voltage 36 VAC
| Model | Rated load (t) | Load chains | Chain size (mm) | Lifting speed, single (m/min) | Lifting speed, dual (m/min) | Lifting motor, single (kW) | Lifting motor, dual (kW) | Trolley speed, single / dual (m/min) | Trolley motor, single / dual (kW) | Trolley flange width (mm) |
|---|---|---|---|---|---|---|---|---|---|---|
| EGFH 10-04 ST/UE | 10 | 4 | 11.2 × 34 | 2.7 | 0.8 / 2.7 | 3 × 2 | 1.1 / 3 × 2 | 11 / 3.6–11 | 0.75 / 0.3–0.75 | 100–178 |
| EGFH 15-06 ST/UE | 15 | 6 | 11.2 × 34 | 1.8 | 0.5 / 1.8 | 3 × 2 | 1.1 / 3 × 2 | 11 / 3.6–11 | 0.75 × 2 / 0.3–0.75 × 2 | 150–220 |
| EGFH 20-08 ST/UE | 20 | 8 | 11.2 × 34 | 1.35 | 0.4 / 1.35 | 3 × 2 | 1.1 / 3 × 2 | 11 / 3.6–11 | 0.75 × 2 / 0.3–0.75 × 2 | 150–220 |
| EGFH 25-10 ST/UE | 25 | 10 | 11.2 × 34 | 1.1 | 0.15 / 1.1 | 3 × 2 | 1.1 / 3 × 2 | 11 / 3.6–11 | 1.1 × 2 / 0.4–1.1 × 2 | 150–220 |
| EGFH 30-12 ST/UE | 30 | 12 | 11.2 × 34 | 0.9 | 0.28 / 0.9 | 3 × 2 | 1.1 / 3 × 2 | 11 / 3.6–11 | 1.1 × 2 / 0.4–1.1 × 2 | 150–220 |
Source: EGON product catalogue. Technical data, dimensions and weights may change without prior notice. Dimension drawings are available on request.
Duty classification
Match the hoist to your duty class
EGON sizes hoists by FEM and ISO duty groups. Estimate your load spectrum and average daily operating time, then read the group from the table.
| Load spectrum | Definition | 1Bm (M3) | 1Am (M4) | 2m (M5) | 3m (M6) | 4m (M7) | 5m (M8) |
|---|---|---|---|---|---|---|---|
| Light | Only occasionally loaded to the maximum, with a medium dead load. | up to 2 | 2–4 | 4–8 | 8–16 | over 16 | — |
| Medium | Usually small loads, but rather often maximum loads. | up to 1 | 1–2 | 2–4 | 4–8 | TBC | over 16 |
| Heavy | Usually medium loads, but frequently maximum loads. | up to 0.5 | 0.5–1 | 1–2 | 2–4 | 4–8 | 8–16 |
| Very heavy | Usually maximum or almost maximum loads. | up to 0.25 | 0.25–0.5 | 0.5–1 | 1–2 | 2–4 | 4–8 |
Average operating time per day: tm = (2 × HW × ASP × AZ) ÷ (60 × V), where HW is the average hook path (m), ASP the cycles per hour, AZ the working hours per day and V the hoisting speed (m/min).
How to choose
7 questions for choosing the right chain hoist
- What are the operating conditions? Environment, temperature, humidity, dust and space.
- What is the specified safe working load? The maximum load capacity for safety.
- To what height must the load be lifted? This sets the chain or rope length and the hoist type.
- What is the required lifting speed? High for production, low for maintenance.
- Must loads be lifted and lowered with great accuracy? Use an inverter or dual-speed motor for precision.
- Is horizontal load travel necessary? Then choose a hoist with a trolley, or a crane system.
- How is the hoist to be controlled? By pendant, remote control or control panel.

After-sales service
Service that goes beyond the price
Every EGON product comes with a team that keeps it safe and running long after installation.
FAQ
Electric Chain Hoist: common questions
Quick answers from the product catalogue.
What lifting capacities do EGON electric chain hoists cover?
The EGON T-Series covers 0.5 to 30 tonnes: stationary suspension models from 0.5 to 5 t, electric trolley standard headroom models from 1 to 5 t, and heavy duty models from 10 to 30 t.
What is the difference between ST and UE chain hoists?
ST models are the stationary suspension type, hung from a fixed point. UE models are the electric trolley standard headroom type, which travel along the beam flange. Heavy duty models from 10 t are offered as ST/UE.
What duty class are EGON chain hoists?
Every model in the T-Series catalogue is rated M5 (ISO), which is group 2m under FEM.
What power supply does an EGON chain hoist need?
AC 380 V, 3 phase, 50 Hz. The control circuit runs at 36 VAC for user safety.
Should I choose a single-speed or dual-speed chain hoist?
Both are available on every model. Dual speed adds a slow speed, for example 2.2 / 6.8 m/min on a 1 t hoist, so the load can be positioned precisely.
Which safety features are standard?
A power-loss brake, double limit switches, a front-motor clutch, reverse phase protection and a 36 VAC control voltage. The load chain is imported FEC / G80 heat-treated alloy steel.
Request a quotation
Let’s find your lifting solution
Free consultation with our sales engineers. Tell us what you need to lift and we will recommend the right hoist for your site.
Call 02-322-0776-8
Email info@egonhoist.com
Hours Monday to Friday, 08:00 to 17:00
Visit 933, 935, 937, 939 Soi Onnut 46, Onnut Road, Suanluang, Bangkok 10250, Thailand
LINE and all contact channels
Scan the QR code for EGON LINE Official and contact channels.